DAIKIN VRV III-S 48K 5 Zone Mini split Ductless Air conditioning Heat pump MODELS
Need a CAD or 3D Model?
DAIKIN VRV III-S 48K 5 Zone Mini split Ductless Air conditioning Heat pump
daikin Hydraulic Pump
DAIKIN VRV III-S 48K 5 Zone Mini split Ductless Air conditioning Heat pump SPECIFICATIONS
DAIKIN VRV III-S 48K 5 Zone Mini split Ductless Air conditioning Heat pump
- New
- DAIKIN AC
- Ductless heat pump
- VRV-S
- Heating amp; cooling
- HEAT PUMP
- Total 1800 square feet
- 48,000 - 54,000 Btu
- kamenzhang2020-07-10 09:46:19
Welcome to my shop! Glad to serve you! Please send your question!
информация о продукте
- New
- DAIKIN AC
- Ductless heat pump
- VRV-S
- Heating amp; cooling
- HEAT PUMP
- Total 1800 square feet
- 48,000 - 54,000 Btu
DAIKIN VRV III-S 48K 5 Zone Mini split Ductless Air conditioning Heat pump Детали Продукта
DAIKIN VRV III-S 48K 5 Zone Mini split Ductless Air conditioning Heat pump
daikin Piston pumps are an important device for hydraulic systems. It relies on the plunger in the cylinder in the reciprocating motion, so that the volume of the sealed working chamber changes to achieve oil absorption, oil pressure. The plunger pump has the advantages of high rated pressure, compact structure, high efficiency and convenient flow regulation.
It is widely used in high pressure, large flow and flow regulation, such as hydraulic press, construction machinery and ship. Daikin plunger pump performance overview is as follows: V-type piston pump, with a unique design swashplate change angle function. Widely used in various places.
Specially designed to maintain low noise performance in the full pressure zone. Integrated by a variety of control methods, can form a system, with energy, miniaturization, low cost and other advantages. Power loss is small, reduce oil temperature rise, optional smaller fuel tank.
Widely used in machine tools, machine Qing, forging, plastic forming machine. Low noise, all the pressure range in each series to achieve a low noise sound operation, high efficiency.
DAIKIN VRV III-S 48K 5 Zone Mini split Ductless Air conditioning Heat pump
V series piston pump: V8, V15, V23, V38, V50, V70.
VD series double pump: VDS11P-S2, VDS12P-S2, VDS13P-S2, VDS14P-S2.
VZ series piston pump: VZ50, VZ63, VZ80, VZ100, VZ130.
<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd"><html ><head><meta HTTP-EQUIV="Content-Type" CONTENT="text/html; charset=utf-8" /><title>Daikin 5 Zones Ductless split AC installed</title></head><body><blockquote>
Daikin VRV-S Include HVAC installation
5 Zones Heating (heat pump) & cooling ductless Air conditioning system
(5 x 12,000 Btu each) Wall mounted, state of the art air conditioning / heat pump system
Connection Flexibility Index: 24,000 to 62,000 Btu, (Option: can be connected to up to 8 zones)
Dsign flexibility
Continuous operation 0ºF DB (-5ºF WB) - 64ºF DB (60ºF WB) in heating mode and 23ºF DB - 115ºF DB in cooling mode.
Long refrigerant lines, up to 1,000 feet of pipe (492 feet max. linear liquid piping length), 165 height difference.
Ability to interface with an external heating system.
Contact information:
PACIFIC HVAC Air conditioner
Daikin, Fujitsu, Mr.slim, Sanyo Authorized contractor
Tel: 201-266-0049
Complete Package:
Daikin VRV-S System + HVAC installation + electric
Duct- Free, No duct work required, outstanding heating & cooling performance, Quite, Efficient, Independent zoning control,
High efficiency variable speed inverter compressor coupled with inverter fan motor for superior part load performance,
</body></html>Delivery: system delivery to the site job included
This system design for use in residential or light commercial applications: house, apartment, office, retail store. and more. electric power 230V, 30 Amp,
Unlike regular ductless split air conditioning system, The VRV-S provides long piping length of 492 ft with total piping length of 1000 ft,
Required only pair of pipes from the outdoor unit and used by REFENET tubing connectors for entire pipe network.
exceptional heating and cooling performance, precise temperature control, The heat pump operate up to -5°F in heating mode, and up to 115°F in cooling mode,
Reach desired temperature in few minutes,
Customers who experienced the VRV-S performance was impressed beyond expect ions,
They will be happy to share the information with you.
Options: The VRV-S 48,000 Btu condenser can be connected to up to 8 indoor units
and can combine any of the following indoor units: Wall mount, ceiling suspended, concealed ceiling, ceiling cassette,
and floor mount unit, indoor unit capacity choices from 7,000 Btu up to 24,000 Btu, ( Total indoor unit capacity must not excited 62,000 Btu)
VRV-S Product brochureSystem: Daikin (1) VRV-S, 48,000 Btu, 230V, 30 Amp, (5 ) Seven Days programmed wired remote, include HVAC installation and parts
Total pipe length up to 1,000 ftInstallation: Professional long experience Authorized Daikin HVAC contractor certified to install VRV systems
The VRV-S is state of the art air conditioning system, keep you comfortable all year round
High performance ductless AC system, fully inverter, quite, super efficient, outstanding heating and cooling performance
with low ambient up to -5°F in heating mode
keep you comfortable in ext ream cold and hot whether. Independent zoning control for each room,
The Daikin VRV-S system enables up to eight separate fan coils to run off of one condensing unit containing an inverter "variable speed"
Single-phase technology is perfect for residential and light commercial applications Smaller capacity allows precise temperature control over every square inch of space Space-saving design and flexible indoor unit options offer quick and easy installation Superior efficiency results in lower energy costs especially under partial load conditions Silent operation ensures comfortable fit in any room Single-supplier reliability. System delivers 80% complete and fully optimized by Daikin,
compressor. All zones can be individually controlled by the use of individual and central (Multi-Zone) controllers and is ideal for the residential,
condominium and light commercial sectors. A feature of particular importance for residential applications is the night set mode, which can be
set on site to function over a 9 hour period during which operating sound is reduced progressively in three increments of 3dBA.
Features and Benefits:
plus has self-diagnostics and one of the best warranties in the industryTechnical Data outdoor unit full specifications
Operating Range: Cooling 23°F – 115°F DB
Heating 0°F DB – 64°F DB -5°F WB – 60°F WB
Compressor: Type Hermetically Sealed Scroll
Quantity 1
Capacity Control Range 29% - 100%
Motor Rating Output 3.1 kW
Fan: Fan Type x Quantity
Propeller Fan x 2
Fan Motor Output 0.070 kW
Airflow Rate 3,740 CFM
Drive Direct Drive
Power Supply:V/PH/Hz 208-230/1/60
Minimum Circuit Amps (MCA) 27 Amps
Maximum Fuse Amps (MFA) 30 Amps
Maximum Starting Current (MSC) 24.1 Amps
Total Over current Amps (TOCA) 27 Amps
Refrigerant & Piping: Refrigerant Type/Charge R-410A / 12.8 lbs
Control Electronic Expansion Valve
Liquid Refrigerant Piping φ3/8” Flare
Suction Gas Refrigerant Piping φ5/8” Flare
Unit Data: Max. Number of Indoor Units 8
Sound Pressure Level at 3 ft 58 dB
Weight 310 lbs
Piping Specifications
Actual Piping Length 492
Equivalent Piping Length 575
Max. Piping Length from
First Distribution Point to Indoor Unit 130
Total Piping Length 1,000
Max. Height between Outdoor & Indoor Units 165
Max. Height between Indoor Units 50Standard Features:
Six year compressor warranty
One year parts warranty
Heating or cooling operation
Inverter driven (variable speed) scroll compressor
VFD controlled outdoor motor fanVRV-S Wall Mounted
VRV-S Concealed (hidden indoor units)
Связаться с Нами
- Email[email protected]
- Адрес
- Рабочий телефон(рабочее время)
- Факс
DAIKIN VRV III-S 48K 5 Zone Mini split Ductless Air conditioning Heat pump Technical Articles
Анализ текущего обслуживания и устранения неисправностей центробежных насосов |
поршневой насос высокого давления разгерметизации вина скелет причины и меры |
С учетом стандартов температуры для моторов и насосов |
daikin Hydraulic Pump CATEGORIES
- PVV
- PV7 - Direct Operated
- VPV
- PSV
- A11V
- Vickers
- PVT29 PUMP
- PVT38 PUMP
- Gold cup P7R series piston pump
- Vickers vane pump
- T6CC vane pump
- PV pump
- PVT6 pump
- yuken Hydraulic Pump
- siemens
- Gold cup P7 pump
- Gold cup P8 pump
- PVT10 PUMP
- PVT15 PUMP
- PVT20 PUMP
- daikin Hydraulic Pump
- Worldcup P8W Pump
- Gold cup P6P series pump
- Gold cup P7P series pump
- Gold cup P8P series pump
- Gold cup P6R series piston pump
- filteration filter elements
- Vickers Hydraulic Pump
- Denison Hydraulic Pump
- Gold cup P6 pump
- Gold cup P11 pump
- Gold cup P14 pump
- Gold cup P24 pump
- Gold cup P30 pump
- parker gear pump
- Rexroth Hydraulic Pump
- Bosch Hydraulic Pump
- A10V(S)O & (A)A10VSO (Series 31)
- A1VO (Series 10)
- A10V(S)O (Series 52)
- A10VSO (Series 32)
- (A)A4VSO (Series 10 & 30)
- A15VSO (Series 10)
- AA4VG (Series 32)
- AA10VG (Series 10)
- Hitachi Hydraulic Pump
- Eaton
- Sauer Danfoss
- vane pumps
- gear pumps
- check valves
- relief valves
- AZPF and AZPN
- AZPG
- PGH
- piston pumps
- Other Pump
- Komatsu Hydraulic Pump
- Linde Hydraulic Pump
- operated directional valves
- PVT47 PUMP
- PVT64 PUMP
- Dansion P080 pump
- Dansion P110 pump
- Dansion P140 pump
- Dansion P200 pump
- Dansion P260Q pump
- WorldcupP6W Pump
- Worldcup P7W Pump
- fans cooling
- piston motors
- pressure swithes
- accessories
- mitsubishi
- Sumitomo Hydraulic Internal Gear Pump
- Gold cup P8R series piston pump
- NACHI Hydraulic Pump
- rexroth pump
- rexroth linear
- rexroth valve
- pressure valves
- solenoid directional valves
- control valves